General Characteristics
Acoustic
- Frequency from 500 kHz to 18 MHz
- Unlimited number of elements, typically 8 to 256
- Versatile, Dynamic, Accuracy or Hard face acoustic technology
- Reproducibility of the inspection through the homogeneity of performance between the elements of the same probe, and between different probes of the same type
Housing
- Ergonomic or basic housing
- Typical interface for attaching wedges is captive screws or lateral flanges with holes.
- High reliability over time thanks to a robust, watertight design, compatible with harsh industrial environments
Cable and connector
- Standard probes come with 3m cable, top or side output.
- Standard connectors are Ipex, hypertronix/FRB, ITT Canon, Tyco, Conec.
Standard configurations
Freq. (MHz) |
Nb elts | Pitch (mm) |
Active length (mm) |
Active width (mm) |
Housing size* (mm) |
10 | 32 | 0.3 | 9.6 | 8 | 17 x 14 x 35 |
10 | 64 | 0.25 | 16 | 10 | 24 x 16 x 35 |
10 | 128 | 0.25 | 32 | 10 | 40 x 18 x 40 |
5 | 16 | 0.6 | 9.6 | 8 | 17 x 14 x 35 |
5 | 32 | 0.5 | 16 | 12 | 24 x 18 x 40 |
5 | 64 | 0.5 | 32 | 15 | 40 x 20 x 40 |
5 | 128 | 0.5 | 64 | 15 | 75 x 22 x 45 |
2.25 | 32 | 1 | 64 | 20 | 40 x 26 x 35 |
2.25 | 64 | 1 | 64 | 20 | 75 x 26 x 35 |
2.25 | 128 | 1 | 128 | 20 | 140 x 28 x 40 |
*indicative values
Options
- Captive screws of lateral flanges for wedge attachment
- Integrated wedge
- Housing customized for the mechanical environment (inspected parts, scanner, wedges, etc)
- Customized connection
- Adaptation to a particular environment (temperature, pressure, radiation, chemical compatibility)
- Halogen-free for nuclear environments
- Water inlets