General characteristics
- IMASONIC piezocomposite technology
- High sensitivity
- Short pulse length
- Designed for field conditions
- Standard housing
Transducers types
|
Recommended configurations according to NF EN ISO 16828 standard |
|||||
IMASONIC reference |
Nominal frequency (MHz) |
Active diameter (mm) |
Thickness < 70mm
|
Thickness 70-300 mm
|
||
Depth (mm)
|
Angle (°)
|
Depth (mm)
|
Angle (°)
|
|||
T0206 | 2 | 6 | 30-70 |
45-60
|
||
T0212
|
2 | 12 | 30-70 |
45-60
|
100-300 | 45-60 |
T0306
|
3.5 | 6 | 30-70 |
45-60
|
30-100
|
45-60 |
T0503
|
5 | 3 | 10-30 | 50-60 |
<10
|
50-70 |
T0506
|
5 | 6 | 10-30 30-70 |
50-60 45-60 |
<10
10-30 |
50-70 45-60 |
T0512 | 5 | 12 | 30-70 | 45-60 | 30-100 | 45-60 |
T0706 | 7.5 | 6 | 10-30 | 50-60 |
<10
|
50-70 |
T1003
|
10 | 3 | <10 10-30 |
50-70 50-60 |
<10 | 50-70 |
T1006
|
10 | 6 | ||||
T1503
|
15 | 3 | <10 | 50-70 | – | – |
Active diameter (mm) | Housing type | Housing length (mm) | Housing diameter (mm) | Thread dimensions (mm) | Connector |
3-6 | standard | 30 | 9.5 | M12 x 1.75 | Lemo 00 |
3-6 | short | 20 | 9.5 | M12 x 1.75 | MCX |
12 | standard | 29 | 17 | M20 x 1.5 | Lemo 00 |